Journal of Medical Imaging and Radiation Sciences
Volume 42, Issue 4 , Pages 179-182 , December 2011

Clinical Implementation of the New MEDRAD XDS Contrast Extravasation Detector for Multidetector Computed Tomography

  • Charbel Saade, BAppSci (MRS), Mast App. Sc. (CT/MRI)

      Affiliations

    • Department of Radiology, Royal Prince Alfred Hospital, Sydney, New South Wales Australia, University of Sydney, Australia
    • Corresponding Author InformationCorresponding author: Charbel Saade, BAppSci (MRS), Mast App. Sc. (CT/MRI), U12/148-152 Regent St Redfern, Sydney, NSW, 2016.
  • ,
  • Patrick Brennan, PhD, HDipR

      Affiliations

    • University of Sydney, Australia

References 

  1. Bellin M-F, Jakobsen JA, Tomassin I, et al. Contrast medium extravasation injury: guidelines for prevention and management. Eur Radiol. 2002;12:2807–2812
  2. Cohan RH, Ellis JH, Garner WL. Extravasation of radiographic contrast material: recognition, prevention, and treatment. Radiology. 1996;200:593–604
  3. Cohan RH, Bullard MA, Ellis JH, et al. Local reactions after injection of iodinated contrast material: detection, management, and outcome. Acad Radiol. 1997;4:711–718
  4. Sistrom CL, Gay SB, Peffly L. Extravasation of iopamidol and iohexol during contrast-enhanced CT: report of 28 cases. Radiology. 1991;180:707–710
  5. Cochran ST, Bomyea K, Sayre JW. Trends in adverse events after IV administration of contrast media. AJR Am J Roentgenol. 2001;176:1385–1388
  6. Jacobs JE, Birnbaum BA, Langlotz CP. Contrast media reactions and extravasation: relationship to intravenous injection rates. Radiology. 1998;209:411–416
  7. Federle MP, Chang PJ, Confer S, et al. Frequency and effects of extravasation of ionic and nonionic ct contrast media during rapid bolus injection. Radiology. 1998;206:637–664
  8. Cademartiri F, van der Lugt A, Luccichenti G, et al. Parameters affecting bolus geometry in CTA: a review. J Comput Assist Tomogr. 2002;26:598–607
  9. Amaral JG, Traubici J, BenDavid G, et al. Safety of power injector use in children as measured by incidence of extravasation. AJR Am J Roentgenol. 2006;187:580–583
  10. Medrad International. XDS Extravasation Detection System Operation and Installation Manual: Warrendale, PA USA 2007.
  11. Silverman PM, Kohan L, Ducic I, et al. Imaging of the liver with helical CT: a survey of scanning techniques. AJR Am J Roentgenol. 1998;170:149–152
  12. Federle MP, Chang PJ, Confer S, et al. Frequency and effects of extravasation of ionic and nonionic CT contrast media during rapid bolus injection. Radiology. 1998;206:637–640
  13. Sinan T, Al-Khawari H, Chishti FA, et al. Contrast media extravasation: manual versus power injector. Med Principles Practice. 2005;14:107–110
  14. Birnbaum BA, Nelson RC, Chezmar JL, et al. Extravasation detection accessory: clinical evaluation in 500 patients. Radiology. 1999;212:431–438
  15. Cohan RH, Dunnick NR, Leder RA, et al. Extravasation of nonionic radiologic contrast media: efficacy of conservative treatment. Radiology. 1990;176:65–67
  16. Medical Professional Liability (MPL) Reporting Claims Database. Tallahassee, FL: Florida Office of Insurance Regulation; 2006;

PII: S1939-8654(11)00051-8

doi: 10.1016/j.jmir.2011.05.003

Journal of Medical Imaging and Radiation Sciences
Volume 42, Issue 4 , Pages 179-182 , December 2011